Platinum Rhodium Thermocouple

Original
price: Negotiable
minimum:
Total supply:
Delivery term: The date of payment from buyers deliver within days
seat: Chongqing
Validity to: Long-term effective
Last update: 2024-04-08 10:41
Browse the number: 140
inquiry
Company Profile
 
 
Product details

Platinum Rhodium thermocouple with highest measurement accuracy of all, and be treated as standard thermocouple. Including S,R and B types, almost be assembly structure. The highest accuracy is ±1℃,and highest using temperature is 1700℃ (B).The thermocouple is mainly applied for oxide environment, and using occasions mainly be high temperature kilns.



 






Technical characteristics




 



1.Elements

•S, R, B types(basing on IEC 60584-1:2013 and GB16839.1 standards).

•0.5mm standard diameter, or can be stretched down to 0.45mm or even 0.4mm diameter to meet cost-saving needs.

•Temperature suggestion and accuracy please refer to Thermocouple Recommended Application Temperature Chart.



2.Protection Tube

•The outer diameter parameters are φ6,8,10,12,16,20 for the assembly method structure

•Our material selections are GH3039, Inconel600, 99%Al2O3, and quartz.



3.Structure

•The ways to make connections are connectors, water-proof heads, explosion-proof heads, etc. Head-mounted temperature transmitter is available for the enclosure.

•Installation methods: no mounting, thread mounting, and flange mounting.

•There are single point, two point and multipoint types to choose from.



 



Platinum Rhodium Thermocouple Conductor Combinations And Characteristics




































Type



Thermoelement



Temperature range ℃



Function Features



Advantages



Disadvantages



S



Ptrh10-Pt



0~1600



Suitable for oxidation atmosphere. High precision, stability is not affected by using time.With oxidation resistance, chemical corrosion resistance, can be used as standard thermocouple.



Not suitable for reducing atmosphere (especially H2, metal vapor) and vacuum environment, high cost.



R



Ptrh13-Pt



0~1600



B



Ptrh30-Ptrh6



600~1700



Suitable for more than 1000℃,with small thermoelectric, oxidation resistance and chemical corrosion resistance



Can't be used below 600℃, low sensitivity.




 



Platinum Rhodium Thermocouple Limit Of Error





































 



Thermoelement



Type



Limits Of Error(±℃)/Effective Temperature Range(℃)



1 class



2 class



3 class



Nobel



Metal



TC



Ptrh10-Pt



S



1.0/600~1100



1+0.003(t-1100)/1100~1600



1.5 or 0.25%t/0~1600



--



Ptrh13-Pt



R



Ptrh30-Ptrh6



B



--



1.5 or 0.25%t/600~1700



4.0 or 0.5%t/600~1700




 






Product details




 

















 






Shock-resistant packaging




 

















 






Our Customers




 





 






Insights into our company




 











































 






Insights into our production




 











Manual Welding









Automatic Welding









Insulation Testing









Laser Marking









Warehouse Managing









Thermocouple Assemble









Vacuum Leak Detection









Surface Polishing









 






Quality Certifications




 













































http://www.duchinsensor.com/

Total0bar [View All]  Related Comments
 
more»Other products

[ Products search ] [ favorites ] [ Tell friends ] [ Print ] [ Close ]